Permeability - Calculate Auxiliary Coordinates (Optional)¶
Category Paths
Follow one of these paths in the Orion user interface, to find the floe.
Solution-based/Hit to Lead/Properties/Permeability
Solution-based/Small Molecule Lead-opt/ADME & Tox/Permeability
Product-based/Molecular Dynamics/OpenMM
Product-based/Molecular Dynamics/WESTPA
Task-based/Molecular Dynamics
Task-based/ADME & Tox Assessment
Description
This floe calculates a pre-defined set of auxiliary coordinates for simulated permeation trajectories. The floe takes a dataset generated by Permeability - Run Permeability Simulation but also requires the associated collection to be accessible.
Check the documentation for a full list of supported auxiliary coordinates.
Promoted Parameters
Title in user interface (promoted name)
Inputs
Input Dataset (in): The dataset(s) to read records from
Required
Type: data_source
Outputs
Output Dataset (out): Output dataset to write to
Required
Type: dataset_out
Default: Permeability Auxiliary
Output Collection (collection): Name of the collection in which to store the simulation output.
Required
Type: collection_sink
Default: Permeability Auxiliary Data
Floe Report (report): The title for the output floe report.
Required
Type: string
Default: Permeability Auxiliary Report
Failure Report (fail_report): Output report to generate upon failure
Type: string
Default: Permeability Auxiliary Failure Report
Additional Information
Reference Permeability Coefficient (Logarithmic, Optional) (ref_perm): This can be a value determined by an experiment or determined by other methods as a reference
for comparison. The reference value should have a unit of cm/s and then converted to the log scale. An error can be included in a pair of parentheses, if available. Example input: -6.0 (0.1). Leave the parameter empty to not change it.
Type: string
Reference Permeability Coefficient Source (Optional) (ref_src): Source of the reference permeability coefficient, which can be the type of the experiment or
the name of the method that used to determine permeability. Leave the parameter empty to not change it.
Type: string
Identification Number for the Molecule (Optional) (mol_id): This can be any identification number (e.g., CHEMBL ID) associated with the molecule.
Leave the parameter empty to not change it.
Type: string
Molecule Name (Optional) (mol_name): The name for the molecule. Leave the parameter empty to not change it.
Type: string
Miscellaneous Parameters
Rerun (rerun): Rerun the calculations even if the result is already present on the input record
Type: boolean
Default: False
Choices: [True, False]
Clean Up (cleanup): Clean up the original west.h5 data.
Type: boolean
Default: True
Choices: [True, False]
Log Verbosity (verbosity): verbose level
Type: string
Default: debug
Choices: [‘info’, ‘warning’, ‘error’, ‘debug’, ‘ddebug’]