Version 1.9.0¶
OEChem 1.9.0¶
New features¶
Added support for reading the
V3000
file format for molecules, queries, and reactions. By default, whether to read theV3000
format will be detected automatically from the header inside.sdf
,.mol
, and.rxn
files.OEGroupBase class added as a container of atoms and bonds inside a OEMolBase to store MDL enhanced stereo information. See the
OEGroupType
namespace for the different types of enhanced stereo information that can be processed. Only the following subset of OEChem functions handle OEGroupBase information at this time:By virtue of the above low level reader functions populating OEGroupBase information,
OEReadMolecule
from aV3000
file format will also populate OEGroupBase information on a molecule.Adding the following predicates for handling OEGroupBase objects on molecules.
OEAssignZap9Radii
has been updated to use the method published in the 2010 Journal of Computer-Aided Molecular Design by Nicholls, Wlodek, and Grant. The old behavior can be accessed by passing constants found in theOEZap9Version
namespace.oemolithread now works with
CDX
files.OEIFlavor.PDB.FORMALCHARGE
input flavor for PDB file reading added. This flavor is provided for advanced users who wish to read the formal charge from the file and do their own bond and hydrogen perception. It is not yet turned on by default.SD data tags and value in
SDF
files can now be up to 64 kilobytes in length, up from the previous limit of just 4 kilobytes.OEMolecularFormula
extended to include hydrogen isotopes deuterium (D
) and tritium (T
) in the molecular formula output. Note, the default behavior has not changed, the user is required to pass an additional parameter to enable this feature.The Amber C-terminal capping residue
OEResidueIndex.NME
is now supported. Support for the Amber C-terminal capping residue OEChem::OEResidueIndex::NMH is incomplete.
Major bug fixes¶
OESubsetMol
will no longer crash non-deterministically when setting theRGroup
parameter totrue
.OEInterface had a rare one time initialization thread safety bug when dealing with molecule parameters that has been fixed.
OEGetResidueName
will now handleOEResidueIndex.GLH
appropriately.OEMCSType.Approximate
search method will now terminate once theOEMCSSearch.GetMaxMatches
limit has been reached. The previous behavior was to keep enumerating all possible matches, then choose the first matches up to the limit. This significantly speeds upOEMCSType.Approximate
searches that results in a lot of matches, e.g., matching a molecule onto itself.Note
It is highly recommended to call
OESuppressHydrogens
before trying to perform a self match on a molecule.
Minor bug fixes¶
OEResidueHydrogens
will now throw an error check when attempting to assign a PDB atom name when there are more than than 9 hydrogens attached to a single atom.
OESystem 1.9.0¶
New features¶
Minor bug fixes¶
OEInterface help messages now only print a reasonable number of digits when printing floating point values.
OEReadCDXFile
andOEReadMolecule
now preserve stereochemistry when loading ChemDraw CDX files. Additionally, some incorrect warning messages have been removed from the CDX file reader.
Documentation changes¶
Figures added to the documentation of
OEMDLCorrectBondStereo
,OEMDLPerceiveBondStereo
, andOEMDLStereoFromBondStereo
to help explain the differences between those functions.
OEPlatform 1.9.0¶
Minor bug fixes¶
OEFile.AbsPath
fixed to not have a leading/
if the directory path specified is empty.
OEBio 1.9.0¶
Major bug fixes¶
The method
OEHierResidue.GetAtom
now correctly interprets the inputOEPDBAtomName
parameter rather than failing to find the requested atom.