Water Sampling Floe
Category Paths
Follow one of these paths in the Orion user interface, to find the floe.
Solution-based/Formulation
Role-based/Formulation Scientist
Product-based/Crystal Structure Prediction
Task-based/Crystal Structure Prediction
Description
This Floe samples waters around each input conformer and assess the relative energy of the resulting dimers. It assumes all input conformers are of the same molecule.
Promoted Parameters
Title in user interface (promoted name)
Energy thresholds (energy_thresholds) type: string: Energy thresholds for water re-sampling stage.Default: 0.0,2.5,5.0 Failed Conformation (failure) type: dataset_out: Dataset containing records with (failed) water sampling.Default: monohydrate_failures Force Field (force_field) type: string: Force Field used in water sampling.Default: ieff3Choices: ieff2, ieff3, smirnoff Hydrogen-Hydrogen deduplication Tolerance (hydrogen_hydrogen_dedup_tol) type: decimal: Hydrogen-Hydrogen deduplication Tolerance.Default: 0.5 Input monomer geometries (in) type: data_source: Dataset containing input monomer geometries for which we want to sample waters. Input reference geometry (in_ref) type: data_source: Dataset containing input reference geometry. Number of waters per site (num_waters_per_site) type: integer: Number of most diverse waters per donor/acceptor site. When zero, all waters in energy window will be kept.Default: 10 Number of waters for re-sampling (num_waters_resampling) type: string: Number of waters per relative energy range for water re-sampling stage.Default: 20,10,5 Output Dataset with results of Water Sampling (out) type: dataset_out: Resulting dataset containing records with Phonon Frequency Spectrum, Crystal Entropy.Default: monohydrate Oxygen-Oxygen deduplication Tolerance (oxygen_oxygen_dedup_tol) type: decimal: Oxygen-Oxygen deduplication Tolerance.Default: 0.26 Dataset with computed QM multipoles (qm_mults) type: dataset_out: Resulting dataset with computed QM Multipoles.Default: qm_mults Multipoles Switch (qm_mults_switch) type: boolean: Boolean switch that controls whether multipoles need to be done on the conformers.Default: True Water RMSD Switch (water_rmsd_switch) type: boolean: When On, compares and filters sampled waters to a reference (experimental) monohydrate.Default: False Water RMSD filtering threshold (water_rmsd_threshold) type: decimal: Water RMSD distances between simulated and reference monohydrates above threshold will be filtered away.Default: 2.0 Memory in MB of the Water Sampling Cube (water_sampling_memory) type: decimal: Memory given to the water sampling cube.Default: 14400 , Min: 256.0, Max: 8589934592